Serial communication problems
If you are having problems communicating with a Morningstar product using a serial connection, try the following:
1. Make sure that the unit is
powered with a battery or power supply. The unit cannot communicate without
power.
2. Verify that the serial cable
is not a Null Modem or cross-over cable.
3. Verify that no other programs
or managers are using the same serial port.
4. Check the serial cable for
continuity using a multimeter. The cable should have continuity from
Pin1<->Pin1, Pin2<->Pin2,...
5. Shut down and restart the PC.
Reattempt connection.
6. Try another PC For products that require the PC MeterBus Serial Adapter (Model: MSC), check the RJ-11 telephone cable. If possible, try another cable. It has been reported that some USB to Serial cables will not work with the MSC because the RS-232 output signal voltages are below the RS-232 electrical specification.
|